Giranel™ Guiding Sheath

Giranel™ Guiding Sheath

When dealing with lesions in the distal end, the Giranel™ Guiding Sheath offers excellent support and resistance to bending, making lesion crossing more efficient.

 Product Feature

  1. Outstanding Vascular Access,
  • The sheath has two hardness, with a soft distal end to reduce vascular trauma.
  • Smooth transition between the sheath and dilator for easy navigation into the vessel.
  • Hydrophilic coating at the distal end for long-lasting lubrication and improved overall passability.

 

  1. Precise Positioning,
  • Radiopaque sheath for tracking of its position.
  • Radiopaque markers at the head end for accurate sheath positioning.

 

  1. Smooth Instrument Access
  • PTFE-coated inner lumen for smooth access and small resistance.
  • Middle stainless steel torsion layer for enhanced resistance to bending and support, establishing stable vascular access.

 

  1. Passive Hemostatic Valve Design
  • Proximal passive hemostatic valve for effective hemostasis and ensuring instrument maneuverability.
  • The side of the hemostatic valve connects a three-way manifold for easy liquid infusion.

Specification Matrix

No.

Specification

Guiding Sheath

Dilator

Inner Diameter(mm)

Outer Diameter (Fr)(mm)

Effective Length(cm)

Tip Form

Outer Diameter(mm)

Inner Diameter for 0.018”GW(mm)

Inner Diameter for 0.035”GW(mm)

Effective Length(cm)

Tip Form

1

KSI-4.0-18/35-55-S2

1.40±0.2

2.01±0.2

55±3.5

S2

1.37±0.2

0.50±0.2

0.95±0.2

60±4

DS2

2

KSI-4.0-18/35-90-S2

1.40±0.2

2.01±0.2

90±3.5

S2

1.37±0.2

0.50±0.2

0.95±0.2

95±4

DS2

3

KSI -4.0-18/35-110-S2

1.40±0.2

2.01±0.2

110±3.5

S2

1.37±0.2

0.50±0.2

0.95±0.2

115±4

DS2

4

KSI -5.0-18/35-45-S1

1.80±0.2

2.31±0.2

45±3.5

S1

1.70±0.2

0.50±0.2

0.95±0.2

50±4

DS1

5

KSI -5.0-18/35-50-S2

1.80±0.2

2.31±0.2

50±3.5

S2

1.70±0.2

0.50±0.2

0.95±0.2

55±4

DS2

6

KSI -5.0-18/35-90-S2

1.80±0.2

2.31±0.2

90±3.5

S2

1.70±0.2

0.50±0.2

0.95±0.2

95±4

DS2

7

KSI -5.0-18/35-110-S2

1.80±0.2

2.31±0.2

110±3.5

S2

1.70±0.2

0.50±0.2

0.95±0.2

115±4

DS2

8

KSI -5.0-18/35-50-S3

1.80±0.2

2.31±0.2

50±3.5

S3

1.70±0.2

0.50±0.2

0.95±0.2

55±4

DS2

9

KSI -5.0-18/35-50-S4

1.80±0.2

2.31±0.2

50±3.5

S4

1.70±0.2

0.50±0.2

0.95±0.2

55±4

DS2

10

KSI -6.0-18/35-45-S1

2.16±0.2

2.69±0.2

45±3.5

S1

2.00±0.2

0.50±0.2

0.95±0.2

50±4

DS1

11

KSI -6.0-18/35-50-S2

2.16±0.2

2.69±0.2

50±3.5

S2

2.00±0.2

0.50±0.2

0.95±0.2

55±4

DS2

12

KSI -6.0-18/35-50-S3

2.16±0.2

2.69±0.2

50±3.5

S3

2.00±0.2

0.50±0.2

0.95±0.2

55±4

DS2

13

KSI -6.0-18/35-50-S4

2.16±0.2

2.69±0.2

50±3.5

S4

2.00±0.2

0.50±0.2

0.95±0.2

55±4

DS2

14

KSI -6.0-18/35-50-S5

2.16±0.2

2.69±0.2

50±3.5

S5

2.00±0.2

0.50±0.2

0.95±0.2

55±4

DS2

15

KSI -7.0-18/35-45-S1

2.48±0.2

3.01±0.2

45±3.5

S1

2.37±0.2

0.50±0.2

0.95±0.2

50±4

DS1

16

KSI -7.0-18/35-50-S2

2.48±0.2

3.01±0.2

50±3.5

S2

2.37±0.2

0.50±0.2

0.95±0.2

55±4

DS2

17

KSI -7.0-18/35-50-S3

2.48±0.2

3.01±0.2

50±3.5

S3

2.37±0.2

0.50±0.2

0.95±0.2

55±4

DS2

18

KSI -7.0-18/35-50-S4

2.48±0.2

3.01±0.2

50±3.5

S4

2.37±0.2

0.50±0.2

0.95±0.2

55±4

DS2

19

KSI -8.0-18/35-45-S1

2.80±0.2

3.32±0.2

45±3.5

S1

2.70±0.2

0.50±0.2

0.95±0.2

50±4

DS1

20

KSI -8.0-18/35-50-S2

2.80±0.2

3.32±0.2

50±3.5

S2

2.70±0.2

0.50±0.2

0.95±0.2

55±4

DS2

21

KSI -8.0-18/35-50-S3

2.80±0.2

3.32±0.2

50±3.5

S3

2.70±0.2

0.50±0.2

0.95±0.2

55±4

DS2

22

KSI -9.0-18/35-50-S2

3.10±0.2

3.60±0.2

50±3.5

S2

3.00±0.2

0.50±0.2

0.95±0.2

55±4

DS2

23

KSI -9.0-18/35-50-S3

3.10±0.2

3.60±0.2

50±3.5

S3

3.00±0.2

0.50±0.2

0.95±0.2

55±4

DS2

24

KSI -10.0-35-50-S3

3.43±0.2

3.98±0.2

50±3.5

S3

3.29±0.2

/

0.95±0.2

55±4

DS2

25

KSI -12.0-35-50-S3

4.00±0.2

4.70±0.2

50±3.5

S3

3.90±0.2

/

0.95±0.2

55±4

DS2